{"created":"2023-06-19T13:30:55.537457+00:00","id":865,"links":{},"metadata":{"_buckets":{"deposit":"6b2925c2-3ca8-405f-bab5-eb2035b2386f"},"_deposit":{"created_by":14,"id":"865","owners":[14],"pid":{"revision_id":0,"type":"depid","value":"865"},"status":"published"},"_oai":{"id":"oai:jrckicn.repo.nii.ac.jp:00000865","sets":["2"]},"author_link":["1698","1616","1650","1727","1729","1743","1653","1856","1857"],"control_number":"865","item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2021-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageStart":"e672","bibliographicVolumeNumber":"8","bibliographic_titles":[{"bibliographic_title":"Acute Medicine & Surgery","bibliographic_titleLang":"en"}]}]},"item_10001_description_19":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Aim\nThe Intensive Care Unit Trigger Tool (ICUTT) was developed to detect adverse events (AEs) in intensive care unit (ICU) patients. The purpose of this study was to determine the validity and reliability of the Japanese version of the ICUTT (ICUTT-J).\n\nMethods\nThe translation of ICUTT was carried out based on the guideline for translation of instruments. Subsequently, two review teams independently reviewed 50 patients' medical records using the ICUTT-J, and agreement regarding the presence and number of AEs was evaluated to ensure reliability.\n\nResults\nThe ICUTT-J was submitted to the authors of the original ICUTT, who confirmed it as being equivalent to the original version. The item-content validity index and scale-content validity index were 1.00 and 1.00, respectively. Interrater reliability showed moderate agreement of κ = 0.52 in terms of the presence of AEs and linear weighting of κ = 0.49 (95% confidence interval, 0.28, 0.71) in terms of the number of AEs.\n\nConclusion\nThis study's findings suggest that the ICUTT-J is valid and moderately reliable for use in ICUs.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Japanese Association for Acute Medicine"},{"subitem_publisher":"日本救急医学会"}]},"item_10001_relation_18":{"attribute_name":"他の資源との関係","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"Acute Medicine & Surgery(Wiley online library)"}],"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1002/ams2.672","subitem_relation_type_select":"DOI"}}]},"item_10001_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"©2021 The Authors. Acute Medicine & Surgery published by John Wiley & Sons Australia, Ltd on behalf of Japanese Association for Acute Medicine"},{"subitem_rights":"This is an open access article under the terms of the Creative Commons Attribution-NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes."}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"2052-8817","subitem_source_identifier_type":"EISSN"}]},"item_10001_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"AIKAWA, Gen","creatorNameLang":"en"},{"creatorName":"相川, 玄","creatorNameLang":"ja"},{"creatorName":"アイカワ, ゲン","creatorNameLang":"ja-Kana"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"SAKURAMOTO, Hideaki","creatorNameLang":"en"},{"creatorName":"櫻本, 秀明","creatorNameLang":"ja"},{"creatorName":"サクラモト, ヒデアキ","creatorNameLang":"ja-Kana"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"大内, 玲","creatorNameLang":"ja"},{"creatorName":"OUCHI, Akira","creatorNameLang":"en"},{"creatorName":"オオウチ, アキラ","creatorNameLang":"ja-Kana"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"小野, 知恵美","creatorNameLang":"ja"},{"creatorName":"ONO, Chiemi","creatorNameLang":"en"},{"creatorName":"オノ, チエミ","creatorNameLang":"ja-Kana"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"星野, 哲也","creatorNameLang":"ja"},{"creatorName":"HOSHINO, Tetsuya","creatorNameLang":"en"},{"creatorName":"ホシノ, テツヤ","creatorNameLang":"ja-Kana"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"城戸, 崇裕","creatorNameLang":"ja"},{"creatorName":"KIDO, Takahiro","creatorNameLang":"en"},{"creatorName":"キド, タカヒロ","creatorNameLang":"ja-Kana"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"井上, 貴昭","creatorNameLang":"ja"},{"creatorName":"INOUE, Yoshiaki","creatorNameLang":"en"},{"creatorName":"イノウエ, ヨシアキ","creatorNameLang":"ja-Kana"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"浅野, 美礼","creatorNameLang":"ja"},{"creatorName":"ASANO, Yoshihiro","creatorNameLang":"en"},{"creatorName":"アサノ, ヨシヒロ","creatorNameLang":"ja-Kana"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"日高, 紀久江","creatorNameLang":"ja"},{"creatorName":"HIDAKA, Kikue","creatorNameLang":"en"},{"creatorName":"ヒダカ, キクエ","creatorNameLang":"ja-Kana"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2022-07-14"}],"displaytype":"detail","filename":"Development of the Japanese version of the Intensive Care Unit Trigger Tool to detect adverse events in critically ill patients.pdf","filesize":[{"value":"313.8 kB"}],"format":"application/pdf","licensetype":"license_9","mimetype":"application/pdf","url":{"label":"本文","url":"https://jrckicn.repo.nii.ac.jp/record/865/files/Development of the Japanese version of the Intensive Care Unit Trigger Tool to detect adverse events in critically ill patients.pdf"},"version_id":"e1982194-237b-485c-bcd1-48260949ef3b"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"adverse event","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"back-translation","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"intensive care","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"trigger tool","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article"}]},"item_title":"Development of the Japanese version of the Intensive Care Unit Trigger Tool to detect adverse events in critically ill patients","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Development of the Japanese version of the Intensive Care Unit Trigger Tool to detect adverse events in critically ill patients","subitem_title_language":"en"}]},"item_type_id":"10001","owner":"14","path":["2"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2022-07-14"},"publish_date":"2022-07-14","publish_status":"0","recid":"865","relation_version_is_last":true,"title":["Development of the Japanese version of the Intensive Care Unit Trigger Tool to detect adverse events in critically ill patients"],"weko_creator_id":"14","weko_shared_id":-1},"updated":"2024-01-24T01:25:08.085898+00:00"}